Posts


PROJECT DESCRIPTION
SEA WATER REVERSE OSMOSIS SYSTEM - 12,000 GPD

COMMERCIAL - HOTEL

In a remote island in Central America, the system provides water to a small - state of the art - hotel

Single pass, single stage. One pressure vessel total, that contains 3 thin-film composite elements in series. The system produces 45.4 m3/day (12,000 GPD or 8.3 GPM) of product water at 38% recovery.

main features

ANCILLARY EQUIPMENT

PHYSICAL DATA & DIMENSIONS :

WhatsApp
Email
Facebook
Twitter
LinkedIn


PROJECT DESCRIPTION
SEAWATER REVERSE OSMOSIS SYSTEM - 3,000 GPD

INDUSTRIAL - DRINKING WATER

The four (4) systems supply water to living quarters exploration facility. Two of them on small towns supporting local population and others in the oil platform for drinking proporses of the exploration team

Four (4) skid mounted seawater reverse osmosis systems set to produce 3,000 GPD of product water.

This system had one a pre-treatment system that consisted of one (1) multimedia filter, one (1) antiscalant injection pump and one (1) ultraviolet lamp for desinfection.

The RO system had three (3) pressure vessels with a single membrane array.

We also integrated a post-treatment system that had one (1) re-mineralization tank and a chlorine injection pump.

main features

ANCILLARY EQUIPMENT

PHYSICAL DATA & DIMENSIONS :

WhatsApp
Email
Facebook
Twitter
LinkedIn