PROJECT DESCRIPTION SEAWATER REVERSE OSMOSIS SYSTEM - 3,000 GPD
INDUSTRIAL - DRINKING WATER
The four (4) systems supply water to living quarters exploration facility. Two of them on small towns supporting local population and others in the oil platform for drinking proporses of the exploration team
Four (4) skid mounted seawater reverse osmosis systems set to produce 3,000 GPD of product water.
This system had one a pre-treatment system that consisted of one (1) multimedia filter, one (1) antiscalant injection pump and one (1) ultraviolet lamp for desinfection.
The RO system had three (3) pressure vessels with a single membrane array.
We also integrated a post-treatment system that had one (1) re-mineralization tank and a chlorine injection pump.
main features
- Inlet actuator valve
- 5 Micron FRP cartridge filter
- 5 HP multistage centrifugal High Pressure Pump
- Motor variable frequency driver (VFD)
- Low- and high-pressure protection
- Two (3) FRP high rated pressure vessel with a one (1) membrane array each
- Clean in place and flush system connections
- NEMA 12 enclosure
- PLC controller
- 15” HMI for operator interface
- Product and reject flowmeter
- Conductivity monitor
- Sample valves
ANCILLARY EQUIPMENT
- One (1) multimedia FRP filters 12” diam. x 62” height (pre-treatment)
- One (1) remineralization FRP filter 12” diam. X 62” height (post-treatment)
- Two (2) activated carbon FRP filter 28” diam. X 62” high (pre-treatment)
- Antiscalant injection system (pre-treatment)
- Chlorine injection system (post-treatment)
PHYSICAL DATA & DIMENSIONS :
- Dimensions: 65" x 73" x 36"
- Weight: - lb.
related information
WhatsApp
Email
Facebook
Twitter
LinkedIn